Boiler pressure too high in your Birmingham home? Why the gauge climbs past 2.5 or 3 bar, what you can safely do about it, and the parts that usually cause it.
Around 1 to 1.5 bar with the heating cold, a little higher when it is running.
A valve left slightly open, or letting by, lets mains water creep in and the pressure rise.
A vessel that has lost its air charge makes the pressure jump every time the heating comes on.
Water from the copper pipe outside means the valve has opened, and it may now need replacing.
With the heating off and cold, bleed a radiator slowly until the gauge reads about 1.5 bar.
A sign of a faulty part rather than something to keep bleeding off.
Boilers have a relief valve that lets water out before pressure gets dangerous. It is still a fault, and the boiler may stop until it is fixed.
Usually 1 to 1.5 bar with the heating cold. Check the boiler manual for the exact figure.
Some rise is normal as water heats. A big jump, into the red, usually means the expansion vessel needs re-charging.
That is usually the pressure relief pipe, meaning the pressure got too high and the valve opened.
Yes, if the vessel itself is sound. If it has failed, it is replaced.
Ask to see the Gas Safe ID card when they arrive. The back lists exactly which appliances that engineer is qualified to work on, and the number can be checked on the Gas Safe Register.
Most combi and system boilers like their pressure at around 1 to 1.5 bar with the heating cold, rising a little as the water warms up. When the needle climbs past 2.5 bar, or into the red zone around 3 bar, something is letting the pressure build, and the boiler will often stop or start dripping water from a pipe outside to protect itself.
The simplest cause is the filling loop. If the system was topped up recently and the valve was left slightly open, or the valve has started to let water through on its own, mains water keeps creeping in and the pressure keeps rising. Check that both taps on the filling loop under the boiler are fully closed.
The next most common cause is the expansion vessel. Water expands as it heats, and the vessel, a small tank with an air cushion inside, absorbs that expansion. Over the years it loses its air charge, so the pressure jumps every time the heating comes on and drops back as it cools. Where that is the fault, the vessel needs re-pressurising or replacing.
When the pressure gets too high, the pressure relief valve opens and lets water out through a copper pipe on the outside wall. That is the safety system working, but once a relief valve has opened a few times it often keeps dripping and needs replacing too. If you see water coming from that pipe, the system needs looking at rather than leaving.
With the heating off and cold, you can let a little pressure out by bleeding a radiator, a towel ready, until the gauge reads about 1.5 bar. If it climbs again, an engineer needs to check the filling loop, the expansion vessel and the relief valve.
A photo of the boiler badge and the display on WhatsApp tells us the make, the model and often the likely part before anyone sets off. If you smell gas, leave the house, do not touch switches and ring the National Gas Emergency line on 0800 111 999 from outside.
A new boiler supplied and fitted by Gas Safe registered engineers - honest advice on the r…
Learn more →An annual service keeps your boiler safe, efficient and - importantly - keeps the warranty…
Learn more →Fast CP12 landlord gas safety certificates for rented homes across Birmingham - …
Learn more →Cold radiators, a noisy system or rooms that never warm up? We repair, upgrade and power f…
Learn more →Homeowner or landlord, we've got Birmingham covered: repairs, servicing, installs and certificates. Leave your details and a local engineer will get back to you fast.
Send a photo of the problem on WhatsApp for the quickest reply, or give us a call. You get a free, no-obligation quote, usually the same day.